⎝⎛真人游戏开户注册⎞⎠

Electronic condensation system
首页 产品中心 预处理系统 电子冷凝系统 You are here: ⎝⎛真人游戏开户注册⎞⎠ProductsPretreatment systemElectronic condensation system
Electronic condensation system
电子冷凝系统 Product name: Electronic condensation system
EC-600 Product model: EC-600
Product introduction:

Electronic cooling dehumidifier is a device used to dehumidify gas. It is mainly used in the pretreatment process before various gas analysis, and it plays the role of improving the accuracy of system analysis and measurement and effectively extending the service life of gas sensors. The cooling part of the dehumidification device adopts semiconductor cooling fins. The device has the characteristics of small size and light weight.

  • main feature
  • Technical Parameters
  • Product configuration
  • Download
采用半导体制冷除湿,能效高,使用寿命长(连续10万小时以上); ♦ The use of semiconductor refrigeration and dehumidification, high energy efficiency and long service life (more than 100,000 consecutive hours);
输入饱和水汽样气条件下,出口样气相对湿度控制在20%RH以内; Under the condition of inputting saturated water vapor sample gas, the relative humidity of the outlet sample gas should be controlled within 20% RH;
内置主动物理预降温系统,输入样气温度可高达500℃; Built-in active physical pre-cooling system, input sample gas temperature can reach up to 500 ℃;
内置超长寿命样气采样泵,流量1-2L/min; Built-in ultra-long-life sample gas sampling pump with flow rate of 1-2L / min;
内置定时排水蠕动泵,排水周期可设置,排水管悬空即可,无须浸入液面以下等繁琐操作; Built-in timing drainage peristaltic pump, the drainage cycle can be set, the drainage pipe can be suspended, and there is no need to immerse into the liquid surface and other complicated operations;
进气、出气接口灵活多变,硬管、软管兼容接入。 Flexible air inlet and outlet ports, compatible with rigid pipes and hoses.

Device size
1) Dimensions: 400 (length) * 300 (width) * 154 (height) mm;
2) Installation size: 270 (length) * 329 (width) mm;
3) Color: white;
4) Weight: about 8kg.
2. Dehumidification performance:
1) Under normal use conditions, the outlet gas dew point temperature is between 1-5 ° C (flow rate is 1-3L / min);
2) When the ambient temperature exceeds 40 ° C, the dew point temperature of the outlet gas will rise proportionally. When the ambient temperature reaches 60 ° C, the instrument will not be damaged after continuous use. When the ambient temperature returns below 40 ° C, its performance can be restored;
3) Pre-cooling time of the instrument: After the instrument is powered on, the pre-cooling time of the gas in a non-flowing state is about 20 minutes at an ambient temperature of 40 ° C. The lower the ambient temperature, the shorter the pre-cooling time.
3. Extreme use conditions:
1) Ambient temperature ≥2 ℃, ≤50 ℃;
2) The inlet gas temperature is ≤ 500 ℃.
4. Cooling method:
1) Use of semiconductor refrigerators;
2) Cooling method: forced air cooling.
5.   Piping:
1) piping material: stainless steel SUS316 is used for joints and heat exchangers, and other PTFE pipes are used;
2) Size of air inlet and air outlet: 8 * 6mm hose (quick-screw) or 6-8mm rigid pipe (clamp sleeve) interface.
6.   Use of gas :
1) Gas used: air or other gases;
2) Gas flow: 1-3L / min.
7.   Power :
AC220V ± 10% / 50Hz, power is about 50W.
8.   Air tightness:
Under 0.1Mpa gas pressure, the drop value does not exceed 1% after 15 minutes.
9. Drainage method :
The peristaltic pump actively drains water. The drainage cycle can be flexibly adjusted according to the humidity of the sample gas.